+91 7349 4479 77
    
/
    
sales@skclab.com

Heat Cold Humidity Testing

Climatic chamber

Specification

Dim
550*400*750(L*W*H)
Temp
-40°C to +180°C
Ramp rate
5°C /min
Humidity
98%

Key Features

  • Rate of Cooling & Heating 2°C /min
  • Temperature stability within +/- 1 ° C
  • External power can be applied or measured to DUT
  • Powerful Eurotherm controller unlimited steps can be programmed.
  • Can be monitored through and controlled through online
  • Auto start after power interruption
  • Safety cutoff limit for temperature settings, ensures, even if main controller malfunction, still DUT will be safe

Climatic chamber

Specification

Dim
600*600*1000(L*W*H)
Temp
-40°C to +180°C
Ramp rate
5°C /min
Humidity
98%

Key Features

  • Rate of Cooling & Heating 2°C /min
  • Temperature stability within +/- 1 ° C
  • External power can be applied or measured to DUT
  • Powerful Eurotherm controller unlimited steps can be programmed.
  • Can be monitored through and controlled through online
  • Auto start after power interruption
  • Safety cutoff limit for temperature settings, ensures, even if main controller malfunction, still DUT will be safe

Climatic chamber

Specification

Dim
1000*980*990(L*W*H)
Temp
-40°C to +190°C
Ramp rate
5°C /min
Humidity
98%

Key Features

  • Rate of Cooling & Heating 2°C /min
  • Temperature stability within +/- 1 ° C
  • External power can be applied or measured to DUT
  • Powerful Eurotherm controller unlimited steps can be programmed.
  • Can be monitored through and controlled through online
  • Auto start after power interruption
  • Safety cutoff limit for temperature settings, ensures, even if main controller malfunction, still DUT will be safe

Thermal chamber

Specification

Dim
520*310*350(L*W*H)
Temp
-40°C to +180°C
Ramp rate
1°C /min
Humidity
98%

Key Features

  • Rate of Cooling & Heating 2°C /min
  • Temperature stability within +/- 1 ° C
  • External power can be applied or measured to DUT
  • Powerful Eurotherm controller unlimited steps can be programmed.
  • Can be monitored through and controlled through online
  • Auto start after power interruption
  • Safety cutoff limit for temperature settings, ensures, even if main controller malfunction, still DUT will be safe

Climatic chamber

Specification

Dim
1200*1200*1200(L*W*H)
Temp
-40°C to +180°C
Ramp rate
5°C /min
Humidity
98%

Key Features

  • Rate of Cooling & Heating 2°C /min
  • Temperature stability within +/- 1 ° C
  • External power can be applied or measured to DUT
  • Powerful Eurotherm controller unlimited steps can be programmed.
  • Can be monitored through and controlled through online
  • Auto start after power interruption
  • Safety cutoff limit for temperature settings, ensures, even if main controller malfunction, still DUT will be safe

Climatic chamber

Specification

Dim
1200*1600*1200(L*W*H)
Temp
-40°C to +180°C
Ramp rate
5°C /min
Humidity
98%

Key Features

  • Rate of Cooling & Heating 2°C /min
  • Temperature stability within +/- 1 ° C
  • External power can be applied or measured to DUT
  • Powerful Eurotherm controller unlimited steps can be programmed.
  • Can be monitored through and controlled through online
  • Auto start after power interruption
  • Safety cutoff limit for temperature settings, ensures, even if main controller malfunction, still DUT will be safe